Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Assunto principal
Intervalo de ano de publicação
1.
J Chromatogr B Biomed Appl ; 653(1): 63-8, 1994 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-8012561

RESUMO

A simple and quick HPLC assay for alcuronium is presented. Its characteristics are: precipitation of plasma proteins by acetonitrile; Spherisorb 5-CN column; acetonitrile-water (46:54, v/v) as mobile phase; flow-rate 1 ml/min; laudanosine 0.06 mg/l as internal standard with plasma; external standard with urine; UV detection at 294 nm; retention time 5.4 min; detection limit 0.025 mg/l; documented linearity: 0.025-2.0 mg/l for plasma and 1.0-80 mg/l for urine; intra- and inter-assay variability below 4%. None of nine drugs used in perioperative pharmacotherapy interfered with the assay. Satisfactory performance was exemplified in a 12-h pharmacokinetic evaluation of two patients.


Assuntos
Alcurônio/análise , Alcurônio/farmacocinética , Anestesia , Cromatografia Líquida de Alta Pressão , Humanos , Indicadores e Reagentes , Espectrofotometria Ultravioleta
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...